Universal intensity regulator for JUNG 1731DD LED bulbs
Universal rotary controller for LED
Switching and lighting regulation
Operation with proper cover
Mounting in a universal flush-mounted box
- Certificación
The device works according to the principle of cutting down phase or up phase cutting
Automatic or manual adjustment of the attenuation principle corresponding to the load
Operating mode indicator set with LED
This device can be used without a neutral conductor.
Connection via Softstart, which extends the life of the lamp
Connection with the last brightness set or connection brightness saved
The operating brightness can be stored continuously
Minimum brightness permanently memorizable
Auxiliary mechanisms can be connected
Electronic protection against short circuits with permanent disconnection at the latest after 7 seconds
Electronic protection against excess temperature
Hotel card function
Possible power extension via power modules (ref. ULZ 1755 REG)
Optional accessories: LED compensation module, ref .: KM LED 230 U
Technical data
Rated voltage: AC 230 V ~
Network frequency: 50/60 Hz
Standby power: approx. 0.35 W
Dissipated power: approx. 4W
Ambient temperature: −5 ... +45 ° C
Connection power at 25 ° C
Incandescent lamps: 20 ... 420 W
230 V halogen lamps: 20 ... 420 W
Electronic transformers: 20 ... 420 W
Electronic transformers with low voltage LED: typ. 20 ... 100 W
Inductive transformers: 20 ... 420 VA
Inductive transformers with low voltage LED: typ. 20 ... 100 VA
230 V LED lamps, dimmable: typ. 3 ... 100 W
Compact, dimmable fluorescent lamps: typ. 3 ... 100 W
With the "LED down phase cut" setting, the connection power for high-voltage LED lamps and electronic transformers with low-voltage LEDs is doubled.
Resistive-capacitive: 20 ... 420 W
Capacitive-inductive: not allowed
Resistive-inductive: 20 ... 420 VA
Resistive and 230V LED: typ. 3 ... 100 W
Resistive and l. compact fluorescents: typ. 3 ... 100 W
Amplifiers: see the "Power extension" manual
Connection: screw terminals
rigid: 1 x 0.5 ... 4.0 mm²
2 x 0.5 ... 2.5 mm²
flexible without toe cap: 1 x 0.5 ... 4.0 mm²
2 x 0.5 ... 2.5 mm²
flexible with toe cap: 1 x 0.5 ... 4.0 mm²
2 x 0.5 ... 1.5 mm²
Number of connectable auxiliary mechanisms
3-wire rotating auxiliary mechanism 1733 DNE: 10
3-wire auxiliary mechanism 1723 NE: 10
2-wire auxiliary mechanism 1720 NE: unlimited
Push buttons: unlimited
Total length of auxiliary line: max. 100 m
Total length of the load conductor:
- Reference
- JUNG 1731DD
- Certification
- CE
- Safety warning
- No