Installation built-in sunroof through-hole 55 mm DICROMAT.
MINI 2 has two output contacts with timings different. Ideal for timed two circuits with a detector. For example lighting and ventilation in bathrooms, lighting and piped music in waiting rooms, lighting and security camera in offices and homes, etc
Parameters adjustable: timing and sensitivity to light.
Power Supply:230 Va.c., 50 Hz
Power breaking:Circuit 1:10 To 230 Va.c./Circuit 2:5, 230 Va.c.
Timing: Circuit 1 from 6s to 12 min./Circuit 2 from 10s to 30 min.
Light sensitivity:adjustable from 5-3.000 lux
Temp. operating:0 ºC to +45 ºC
Degree of protection:IP 20 according to en 60529
Detection angle:360 °
Field of detection:Up to 7 m in diameter
Maximum loads
Incandescent lamps:2000 W
Fluorescent:100 VA
Halogen low-voltage:1000 VA
Halogens (230V AC):2000 W
Lamps low power consumption:100 VA
Lamps leds:50 VA